Rotary Encoders
Absolute and incremental encoders for angle, speed and position — CANopen absolute, HTL/TTL incremental, and an explosion-proof version.
Absolute or incremental?
- Absolute (ADE / ABE / AGE / EXABE): the encoder always knows its position, even after a power cut. Single-turn 14-bit, multi-turn 16-bit, ±0.1° absolute accuracy, CANopen.
- Incremental (ZDE / ZCE): outputs A / B / Z square-wave pulses for speed and relative position. 1–16,384 pulses per revolution (default 4,096), HTL or TTL.
How to choose
- Need position after power-off? Take an absolute encoder. Multi-turn keeps count across revolutions: ABE and ADE use a Hall battery design; AGE uses a Hall multi-stage gear design.
- Measuring speed or counting pulses? Take an incremental encoder (ZDE / ZCE).
- Explosive atmosphere? EXABE, stainless steel, Ex db IIC T4 Gb / Ex tb IIIC T130°C Db.
- Size: ADE / ZDE are size 36; ABE / AGE / ZCE are size 60.
The range at a glance
ADE — Absolute, Size 36
Compact absolute encoder, Hall battery multi-turn. About 130 g.
ABE / AGE — Absolute, Size 60
ABE: Hall battery multi-turn. AGE: Hall multi-stage gear multi-turn.
EXABE — Explosion-Proof
Stainless steel absolute encoder for petroleum, chemical and similar environments.
ZDE — Incremental, Size 36
Compact incremental encoder, A / A−, B / B−, Z / Z− outputs.
ZCE — Incremental, Size 60
Size 60 incremental encoder, same signal set as ZDE.
Which one fits?
Absolute for position, incremental for speed. Tell us the shaft, mounting and interface — we will confirm the model code.
Compare models
| Model | Type | Resolution | Interface | Protection | Weight |
|---|---|---|---|---|---|
| ADE | Absolute, size 36 | 14-bit single-turn / 16-bit multi-turn | CANopen | IP67 | ~130 g |
| ABE | Absolute, size 60 (Hall battery multi-turn) | 14-bit single-turn / 16-bit multi-turn | CANopen | IP67 | ~230 g |
| AGE | Absolute, size 60 (Hall gear multi-turn) | 14-bit single-turn / 16-bit multi-turn | CANopen | IP67 | ~230 g |
| EXABE | Absolute, explosion-proof | 14-bit single-turn / 16-bit multi-turn | CANopen | IP67 | ~1,200 g |
| ZDE | Incremental, size 36 | 1–16,384 ppr (default 4,096) | HTL / TTL | IP67 | ~130 g |
| ZCE | Incremental, size 60 | 1–16,384 ppr (default 4,096) | HTL / TTL | IP67 | ~230 g |
All encoders: −40 to +85 °C, 6,000 rpm max, axial load < 40 N, radial load < 80 N, starting torque ≤ 2.5 Ncm, flange / blind-hole mounting. Absolute: 9–36 V DC, 18 mA @ 24 V DC, ±0.1° absolute accuracy. Incremental: 4.75–5 V DC / 9–36 V DC, 200 kHz max response frequency.
Frequently asked questions
Absolute or incremental — which do I need?
Absolute if the controller must know the position right after power-on. Incremental if you only need speed or relative movement.
What is the difference between ABE and AGE?
Both are size 60 absolute encoders with 16-bit multi-turn. ABE uses a Hall battery multi-turn design; AGE uses a Hall multi-stage gear design.
Is there an explosion-proof version?
Yes — EXABE, stainless steel, marked Ex db IIC T4 Gb and Ex tb IIIC T130°C Db.
What interfaces are available?
Absolute encoders: CANopen. Incremental encoders: HTL or TTL, A / A−, B / B−, Z / Z−.